22 research outputs found

    Does urethral competence affect urodynamic voiding parameters in women with prolapse?

    Full text link
    Aims To (1) compare voiding parameters and (2) correlate symptoms and urodynamic findings in women with pelvic organ prolapse (POP) and varying degrees of urethral competence. Methods We compared three groups of women with stages II–IV POP. Groups 1 and 2 were symptomatically stress continent women participating in the Colpopexy and Urinary Reduction Efforts (CARE) trial; during prolapse reduction before sacrocolpopexy, Group 1 (n = 67) did not have and Group 2 (n = 84) had urodynamic stress incontinence (USI) during prolapse reduction. Group 3 participants (n = 74), recruited specifically for this study, had stress urinary incontinence (SUI) symptoms and planned sacrocolpopexy. Participants completed standardized uroflowmetry, pressure voiding studies, and validated symptom questionnaires. Results Subjects' median age was 61 years, median parity 3 and 87% had stage III or IV POP. Fourteen percent of women in Group 3 demonstrated USI without, and 70% with, prolapse reduction. Women in Groups 2 and 3 had more detrusor overactivity (DO) than Group 1 (17 and 24% vs. 6%, P  = 0.02) and detrusor overactivity incontinence (DOI) (15 and 8% vs. 0%, P  = 0.004). Based on the Blaivis–Groutz nomogram, 60% of all women were obstructed. Post-void residual volume (PVR), peak flow rate, detrusor pressure at peak flow, voiding mechanisms, voiding patterns, obstruction and urinary retention did not differ among groups. Women in Group 3 had higher irritative and obstructive symptom scores than Group 1 or 2; neither score differed by presence of DO nor obstruction, respectively. Conclusion Women with POP have significant rates of urodynamic obstruction and retention, independent of their continence status. Symptoms of obstruction and retention correlate poorly with urodynamic findings. Neurourol. Urodynam. 26:1030–1035, 2007. © 2007 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/57365/1/20436_ftp.pd

    Hidden Silicon-Vacancy Centers in Diamond

    Get PDF
    We characterize a high-density sample of negatively charged silicon-vacancy (SiV^-) centers in diamond using collinear optical multidimensional coherent spectroscopy. By comparing the results of complementary signal detection schemes, we identify a hidden population of \ce{SiV^-} centers that is not typically observed in photoluminescence, and which exhibits significant spectral inhomogeneity and extended electronic T2T_2 times. The phenomenon is likely caused by strain, indicating a potential mechanism for controlling electric coherence in color-center-based quantum devices

    Two-Year Outcomes After Sacrocolpopexy With and Without Burch to Prevent Stress Urinary Incontinence

    Get PDF
    To report anatomic and functional outcomes 2 years after sacrocolpopexy in stress-continent women with or without prophylactic Burch colposuspension

    Racial Differences in Pelvic Anatomy by Magnetic Resonance Imaging

    Get PDF
    To use static and dynamic magnetic resonance imaging (MRI) to compare dimensions of the bony pelvis and soft tissue structures in a sample of African-American and white women

    Magnetic resonance assessment of pelvic anatomy and pelvic floor disorders after childbirth

    Get PDF
    To compare pelvic anatomy, using magnetic resonance imaging (MRI), between women with or without pelvic floor disorders 6-12 months after a first delivery

    A multicentered comparison of measurements obtained with microtip and external water pressure transducers

    Full text link
    This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip–water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/45850/1/192_2005_Article_27.pd

    Prevalence and burden of overactive bladder in the United States

    Full text link
    Context: the National Overactive BLadder Evaluation (NOBLE) Program was initiated to better understand the prevalence and burden of overactive bladder in a broad spectrum of the United States population. Objective: to estimate the prevalence of overactive bladder with and without urge incontinence in the US, assess variation in prevalence by sex and other factors, and measure individual burden. Design: US national telephone survey using a clinically validated interview and a follow-up nested study comparing overactive bladder cases to sex- and age-matched controls. Setting: noninstitutionalized US adult population. Participants: a sample of 5,204 adults ≥18 years of age and representative of the US population by sex, age, and geographical region. Main outcome measures: prevalence of overactive bladder with and without urge incontinence and risk factors for overactive bladder in the US. In the nested case-control study, SF-36, CES-D, and MOS sleep scores were used to assess impact. Results: the overall prevalence of overactive bladder was similar between men (16.0%) and women (16.9%), but sex-specific prevalence differed substantially by severity of symptoms. In women, prevalence of urge incontinence increased with age from 2.0% to 19% with a marked increase after 44 years of age, and in men, increased with age from 0.3% to 8.9% with a marked increase after 64 years of age. Across all age groups, overactive bladder without urge incontinence was more common in men than in women. Overactive bladder with and without urge incontinence was associated with clinically and significantly lower SF-36 quality-of-life scores, higher CES-D depression scores, and poorer quality of sleep than matched controls. Conclusions: the NOBLE studies do not support the commonly held notion that women are considerably more likely than men to have urgency-related bladder control problems. The overall prevalence of overactive bladder does not differ by sex; however, the severity and nature of symptom expression does differ. Sex-specific anatomic differences may increase the probability that overactive bladder is expressed as urge incontinence among women compared with men. Nonetheless, overactive bladder, with and without incontinence, has a clinically significant impact on quality-of-life, quality-of-sleep, and mental health, in both men and women.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42170/1/s00345-002-0301-4.pd
    corecore